| Model | Specifications | ||||||
|---|---|---|---|---|---|---|---|
| HPC-004SL (for Japan) |
HPC- 100HL-E |
HPC- 125HL-E |
HPC- 250HL-E |
HPC- 500HL-E |
|||
![]() |
Phase | 1-Phase | 3-Phase | 3-Phase | 3-Phase | 3-Phase | |
| Output Operating Method |
Grid-Tied Inverter |
Grid-Tied Inverter |
Grid-Tied Inverter |
Grid-Tied Inverter |
Grid-Tied Inverter |
||
| Design Concept | Transformerless | ||||||
![]() |
Max. Input Voltage | 390Vdc | 880Vdc | 880Vdc | 900Vdc | 900Vdc | |
| Nominal Voltage | 250Vdc | 635Vdc | 635Vdc | 650Vdc | 650Vdc | ||
| MPPT Voltage Range | 100~380Vdc | 450~820Vdc | 450~820Vdc | 450~820Vdc | 450~820Vdc | ||
| Max. Input Voltage | 25Adc | 234Adc | 292Adc | 625Adc | 1,140Adc | ||
![]() |
Nominal AC Power | 4kW | 100kW | 125kW | 250kW | 500kW | |
| Nominal AC Voltage | 202V, +10%/-12% |
290V, +10%/-12% |
275V, +10%/-12% |
275V, +10%/-12% |
|||
| Nominal AC Current | 19.8A | 199A | 249A | 540A | 1,050A | ||
| Nominal AC Frequency | 50Hz/60Hz | ||||||
| THD of AC Current | < 5% Total (<3% Individual) at rated power | ||||||
![]() |
Max. Efficiency | 95.0% | 98.0% | 98.0% | 98.0% | 98.0% | |
| European Efficiency | 94.5% | 97.7% | 97.7% | 97.6% | 97.5% | ||
| Power Factor | >0.95 | >0.99 | >0.99 | >0.99 | >0.99 | ||
| Protection Degree | IP20 | IP20 | IP20 | IP20 | IP20 | ||
| Operating Temperature | -10°C~40°C | -10°C~40°C | -10°C~40°C | -20°C~45°C | -20°C~45°C | ||
![]() |
Width/Depth/Height [mm] | 480/120/ 280 |
1,000/800/ 2,095 |
1,000/800/ 2,095 |
1,800/750/ 2,150 |
2,600/800/ 2,080 |
|
| Weight | 14kg | 800kg | 800kg | 1,170kg | 1,550kg | ||
| Protective Functions | DC Over-/Under-Voltage, AC Line Over-/Under-Voltage, AC Line Frequency Failure, AC Line Failure, Anti-Islanding Protection, Overheating | ||||||
※ Specifications subject to change without prior notice.

| Model | Specifications | ||||||
|---|---|---|---|---|---|---|---|
| HPC- 050HT-E |
HPC- 100HT-E |
HPC- 250HT-E |
Solar Station | ||||
| HPS- 500MT-E |
HPS- 1000MT-E |
||||||
![]() |
Phase | 3-Phase | 3-Phase | 3-Phase | 3-Phase | 3-Phase | |
| Operating Method | Grid-Tied Inverter |
Grid-Tied Inverter |
Grid-Tied Inverter |
Grid-Tied Inverter |
Grid-Tied Inverter |
||
| Design Concept | Low-Frequency Transformer | Medium Voltage | |||||
| [△-Y] | [△-Y] | [△-Y] | |||||
![]() |
Max. Input Voltage | 650Vdc | 650Vdc | 880Vdc | 900Vdc | 900Vdc | |
| Nominal Voltage | 450Vdc | 450Vdc | 635Vdc | 650Vdc | 650Vdc | ||
| MPPT Voltage Range | 300~600Vdc | 300~600Vdc | 450~820Vdc | 450~820Vdc | 450~820Vdc | ||
| Max. Input Voltage | 175Adc | 350Adc | 580Adc | 2 x 625Adc | 2 x 1,140Adc | ||
![]() |
Nominal AC Power | 50kW | 100kW | 250kW | 500kW | 1,000kW | |
| Nominal AC Voltage | 400V, +10%/-12% | 20kV, +10%/-12% | |||||
| Nominal AC Current | 72A | 144A | 361A | 14.4A | 28.9A | ||
| Nominal AC Frequency | 50Hz/60Hz | ||||||
| THD of AC Current | < 5% Total (<3% Individual) at rated power | ||||||
![]() |
Max. Efficiency | 95.8% | 96.7% | 96.9% | 97.0% | 97.0% | |
| European Efficiency | 95.0% | 96.3% | 96.4% | 96.5% | 96.5% | ||
| Power Factor | >0.99 | >0.99 | >0.99 | >0.99 | >0.99 | ||
| Protection Degree | IP20 | IP20 | IP20 | IP54 | IP54 | ||
| Operating Temperature | -10°C~40°C | -10°C~40°C | -20°C~40°C | -20°C~45°C | -20°C~45°C | ||
![]() |
Width/Depth/Height [mm] | 800/700/ 1,994 |
1,000/800/ 2,095 |
2,200/850/ 2,215 |
5,300/3,000/ 3,100 |
5,600/3,000/ 3,100 |
|
| Weight | 800kg | 1,250kg | 2,350kg | approx. 28t | approx. 32t | ||
| Protective Functions | DC Over-/Under-Voltage, AC Line Over-/Under-Voltage, AC Line Frequency Failure, AC Line Failure, Anti-Islanding Protection, Overheating | ||||||